{"id":1080,"date":"2019-10-15T08:18:53","date_gmt":"2019-10-15T07:18:53","guid":{"rendered":"http:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/?p=1080"},"modified":"2019-11-30T20:41:45","modified_gmt":"2019-11-30T19:41:45","slug":"odstraneni-drevin-ohrozujici-bezpecny-a-spolehlivy-provoz-elektrickeho-distribucniho-zarizeni","status":"publish","type":"post","link":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/nezarazene\/odstraneni-drevin-ohrozujici-bezpecny-a-spolehlivy-provoz-elektrickeho-distribucniho-zarizeni\/","title":{"rendered":"Odstran\u011bn\u00ed d\u0159evin ohro\u017euj\u00edc\u00ed bezpe\u010dn\u00fd a spolehliv\u00fd provoz elektrick\u00e9ho distribu\u010dn\u00edho za\u0159\u00edzen\u00ed"},"content":{"rendered":"<p>V\u00e1\u017een\u00ed vlastn\u00edci a u\u017eivatel\u00e9 pozemk\u016f,<\/p>\n<p>dovolte, abychom v\u00e1s upozornili na nutnost dodr\u017een\u00ed z\u00e1kona \u010d. 458\/2000 Sb. (energetick\u00fd z\u00e1kon) a povinnosti, kter\u00e9 z n\u011bj plynou.<\/p>\n<p>Na z\u00e1klad\u011b tohoto z\u00e1kona a dle platn\u00fdch norem (PNE 33 0000-6, PNE 33 3300, PNE 33 3301, PNE 33 3302) <strong>v\u00e1s \u017e\u00e1d\u00e1me o odstran\u011bn\u00ed d\u0159evin ohro\u017euj\u00edc\u00edch bezpe\u010dn\u00fd a spolehliv\u00fd provoz elektrick\u00e9ho distribu\u010dn\u00edho za\u0159\u00edzen\u00ed.<\/strong><\/p>\n<p>Odstran\u011bn\u00ed, pros\u00edme, prove\u010fte podle n\u00ed\u017ee uveden\u00e9ho v\u00fdpisu z p\u0159edpis\u016f tak, aby byla dodr\u017eena maxim\u00e1ln\u00ed v\u00fd\u0161ka porostu.<\/p>\n<p>Ochrann\u00e9 p\u00e1smo je vymezeno vzd\u00e1lenost\u00ed od krajn\u00edho vodi\u010de a je r\u016fzn\u00e9 pro jednotliv\u00e9 nap\u011b\u0165ov\u00e9 hladiny. Z\u00e1kon a normy rovn\u011b\u017e ur\u010duj\u00ed minim\u00e1ln\u00ed vzd\u00e1lenost porostu od veden\u00ed, kterou je nutn\u00e9 dodr\u017eet, a bezpe\u010dnou vzd\u00e1lenost pro pr\u00e1ci takto:<\/p>\n<ul>\n<li>V lesn\u00edch pr\u016fsec\u00edch jsou vlastn\u00edci \u010di u\u017eivatel\u00e9 pozemk\u016f povinni umo\u017enit zam\u011bstnanc\u016fm spole\u010dnosti E.ON Distribuce, a.s., nebo touto spole\u010dnost\u00ed zmocn\u011bn\u00fdm zhotovitel\u016fm udr\u017eovat voln\u00fd pruh pozemku o \u0161\u00ed\u0159ce 4 m po jedn\u00e9 stran\u011b z\u00e1klad\u016f podp\u011brn\u00fdch bod\u016f (sloup\u016f) nadzemn\u00edho veden\u00ed.<\/li>\n<li>V p\u0159\u00edpad\u011b, \u017ee p\u0159i odstran\u011bn\u00ed porostu v bl\u00edzkosti veden\u00ed nem\u016f\u017ee b\u00fdt bezpe\u010dn\u00e1 vzd\u00e1lenost pro pr\u00e1ci dodr\u017eena a bezpe\u010dnost osob, technick\u00fd stav veden\u00ed nebo jeho provoz by mohly b\u00fdt ohro\u017eeny, mohou b\u00fdt pr\u00e1ce prov\u00e1d\u011bny pouze se souhlasem spole\u010dnosti E.ON \u010cesk\u00e1 republika, s.r.o.,a to za podm\u00ednek pro tuto pr\u00e1ci stanoven\u00fdch.<\/li>\n<li>Pokud stav stromov\u00ed nebude odpov\u00eddat v\u00fd\u0161e uveden\u00fdm podm\u00ednk\u00e1m, oslov\u00ed v\u00e1s z\u00e1stupce E.ON Distribuce, a.s., formou dopisu, ve kter\u00e9m budou uvedeny informace o proveden\u00ed odstran\u011bn\u00ed a o\u0159ezu d\u0159evin na n\u00e1klady E.ON Distribuce, a.s.<\/li>\n<\/ul>\n<p>Vlastn\u00edk \u010di u\u017eivatel nemovitosti, kter\u00fd neprovede o\u0159ez a odklizen\u00ed d\u0159evin, je povinen v\u00fdkon \u010dinnosti v ochrann\u00e9m p\u00e1smu provozovateli distribu\u010dn\u00ed soustavy umo\u017enit. V opa\u010dn\u00e9m p\u0159\u00edpad\u011b, na z\u00e1klad\u011b zji\u0161t\u011bn\u00ed poru\u0161en\u00ed pr\u00e1vn\u00edch p\u0159edpis\u016f, m\u016f\u017ee Energetick\u00fd regula\u010dn\u00ed \u00fa\u0159ad ud\u011blit vlastn\u00edk\u016fm \u010di u\u017eivatel\u016fm nemovitost\u00ed pokutu.<\/p>\n<p>Odstran\u011bn\u00ed a o\u0159ez d\u0159evin prov\u00e1d\u011bjte, pros\u00edm, pr\u016fb\u011b\u017en\u011b.<\/p>\n<p>Pro p\u0159\u00edpadn\u00e9 dal\u0161\u00ed informace volejte E.ON Z\u00e1kaznickou linku <a href=\"tel:+420800773322\">800 77 33 22<\/a> nebo nav\u0161tivte <a href=\"https:\/\/www.eon-distribuce.cz\/\">www.eon-distribuce.cz<\/a>.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Hladiny nap\u011bt\u00ed (VN)<\/th>\n<th>Ochrann\u00e9 p\u00e1smo<\/th>\n<th>V\u00fd\u0161ka porostu<\/th>\n<\/tr>\n<tr>\n<td>Nadzemn\u00ed veden\u00ed | nap\u011bt\u00ed od 1 kV do 35 kV<\/td>\n<td>7 m od krajn\u00edho vodi\u010de<\/td>\n<td>maxim\u00e1ln\u011b 3 m<\/td>\n<\/tr>\n<tr>\n<td>Nadzemn\u00ed veden\u00ed | nap\u011bt\u00ed nad 35 kV do 110 kV v\u010detn\u011b<\/td>\n<td>12 m od krajn\u00edho vodi\u010de<\/td>\n<td>maxim\u00e1ln\u011b 3 m<\/td>\n<\/tr>\n<tr>\n<td>Podzemn\u00ed veden\u00ed | do nap\u011bt\u00ed 110 kV v\u010detn\u011b<\/td>\n<td>1 m od krajn\u00edho kabelu<\/td>\n<td>nesm\u00ed b\u00fdt \u017e\u00e1dn\u00fd porost<\/td>\n<\/tr>\n<tr>\n<th>Hladiny nap\u011bt\u00ed<\/th>\n<th>Bezpe\u010dn\u00e1 vzd\u00e1lenost pro pr\u00e1ci<\/th>\n<th>Vzd\u00e1lenost porostu od veden\u00ed<\/th>\n<\/tr>\n<tr>\n<td>Veden\u00ed NN | n\u00edzk\u00e9 nap\u011bt\u00ed (400\/230 V)<\/td>\n<td>1 m od veden\u00ed<\/td>\n<td>alespo\u0148 2 m<\/td>\n<\/tr>\n<tr>\n<td>Veden\u00ed VN | vysok\u00e9 nap\u011bt\u00ed (22 kV)<\/td>\n<td>2 m od veden\u00ed<\/td>\n<td>alespo\u0148 3,6 m<\/td>\n<\/tr>\n<tr>\n<td>Veden\u00ed VVN | velmi vysok\u00e9 nap\u011bt\u00ed (110 kV)<\/td>\n<td>3 m od veden\u00ed<\/td>\n<td>alespo\u0148 4,5 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Z\u00e1sady pro prov\u00e1d\u011bn\u00ed odstra\u0148ov\u00e1n\u00ed a o\u0159ez\u016f d\u0159evin<\/h2>\n<p>Odstran\u011bn\u00ed nebo o\u0159ez d\u0159evin se \u0159\u00edd\u00ed ustanoven\u00edmi z\u00e1kona \u010d. 458\/200 Sb. (Energetick\u00fd z\u00e1kon, d\u00e1le jen EZ) a p\u0159edpisy PNE 33 0000-6, PNE 33 3300, PNE 33 3301, PNE 33 3302. V souladu s \u00a746 EZ jsou venkovn\u00ed veden\u00ed s nap\u011bt\u00edm vy\u0161\u0161\u00edm ne\u017e 1 kV a elektrick\u00e9 stanice chr\u00e1n\u011bny ochrann\u00fdmi p\u00e1smy. Ochrann\u00e9 p\u00e1smo (d\u00e1le jen OP) venkovn\u00edho veden\u00ed je souvisl\u00fd prostor vymezen\u00fd svisl\u00fdmi rovinami veden\u00fdmi po obou stran\u00e1ch veden\u00ed ve vodorovn\u00e9 vzd\u00e1lenosti m\u011b\u0159en\u00e9 kolmo na veden\u00ed.<\/p>\n<p>Vzd\u00e1lenosti OP od krajn\u00edho vodi\u010de na ob\u011b strany jsou uvedeny v tabulce \u010d. 1.<\/p>\n<table>\n<caption>Tabulka \u010d. 1: Ochrann\u00e1 p\u00e1sma veden\u00ed dle nap\u011b\u0165ov\u00fdch hladin, * veden\u00ed vybudovan\u00e1 do 31. 12. 1994<\/caption>\n<tbody>\n<tr>\n<th>Jmenovit\u00e1 nap\u011bt\u00ed AC (kV)<\/th>\n<th>Hol\u00e9 vodi\u010de (m)<\/th>\n<th>Vodi\u010de se z\u00e1kladn\u00ed izolac\u00ed (m)<\/th>\n<th>Izolovan\u00fd kabelov\u00fd syst\u00e9m (m)<\/th>\n<\/tr>\n<tr>\n<td>Nad 1 do 35 v\u010detn\u011b<\/td>\n<td>7 (10) *<\/td>\n<td>2<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Nad 35 do 110 v\u010detn\u011b<\/td>\n<td>12 (15) *<\/td>\n<td>5<\/td>\n<td>2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Podzemn\u00ed veden\u00ed do 110 kV v\u010detn\u011b m\u00e1 ochrann\u00e9 p\u00e1smo 1 m. V ochrann\u00e9m p\u00e1smu podzemn\u00edho veden\u00ed je zak\u00e1z\u00e1no vysazovat trval\u00e9 porosty a p\u0159ej\u00ed\u017ed\u011bt veden\u00ed mechanizmy o celkov\u00e9 hmotnosti nad 6 t.<\/p>\n<p>V lesn\u00edch pr\u016fsec\u00edch je ochrann\u00e9 p\u00e1smo:<\/p>\n<ul>\n<li>pro nap\u011b\u0165ovou hladinu nad 1 kV do 35 kV v\u010detn\u011b <strong>sn\u00ed\u017eeno v\u017edy na 7 m<\/strong>,<\/li>\n<li>pro nap\u011b\u0165ovou hladinu nad 35 kV do 110 kV v\u010detn\u011b <strong>sn\u00ed\u017eeno v\u017edy na 12 m<\/strong>.<\/li>\n<\/ul>\n<p>V lesn\u00edch pr\u016fsec\u00edch se mus\u00ed po jedn\u00e9 stran\u011b z\u00e1klad\u016f sloup\u016f nadzemn\u00edho veden\u00ed udr\u017eovat voln\u00fd pruh pozemk\u016f o \u0161\u00ed\u0159ce 4 m, pokud je pro provozovatele distribu\u010dn\u00ed soustavy takov\u00fd voln\u00fd pruh pot\u0159eba, a to zejm\u00e9na s ohledem na pohyb mechanizace v p\u0159\u00edpad\u011b odstra\u0148ov\u00e1n\u00ed poruchy.<\/p>\n<p>V ochrann\u00e9m p\u00e1smu nadzemn\u00edho veden\u00ed je zak\u00e1z\u00e1no vysazovat chmelnice a nech\u00e1vat r\u016fst porosty nad v\u00fd\u0161ku 3 m.<\/p>\n<p>Veden\u00ed NN ochrann\u00e9 p\u00e1smo nem\u00e1, ale na vzd\u00e1lenost porost\u016f od vodi\u010d\u016f se vztahuje norma PNE 33 3302, tzv. nejkrat\u0161\u00ed vzd\u00e1lenosti.<\/p>\n<h2>Rozsah proveden\u00ed o\u0159ez\u016f<\/h2>\n<ul>\n<li>U veden\u00ed VN, VVN se z\u00e1sah prov\u00e1d\u00ed v rozsahu ochrann\u00e9ho p\u00e1sma. Ochrann\u00e1 p\u00e1sma jsou pro jednotliv\u00e9 nap\u011b\u0165ov\u00e9 hladiny uvedena v tab. \u010d. 1.<\/li>\n<li>Pro veden\u00ed NN, VN, VVN je v tab. \u010d. 2 uvedena nejkrat\u0161\u00ed doporu\u010den\u00e1 vzd\u00e1lenost porostu od vodi\u010d\u016f venkovn\u00edho veden\u00ed &#8211; na tuto vzd\u00e1lenost mus\u00ed b\u00fdt porosty pr\u016fb\u011b\u017en\u011b okle\u0161\u0165ov\u00e1ny (z d\u016fvodu ro\u010dn\u00edho p\u0159\u00edr\u016fstku \u010di vych\u00fdlen\u00ed porostu p\u0159i v\u011btru).<\/li>\n<li>U elektrick\u00fdch stanic se z\u00e1sah prov\u00e1d\u00ed v rozsahu ochrann\u00e9ho p\u00e1sma, kter\u00e9 je vymezeno svisl\u00fdmi rovinami ve vodorovn\u00e9 vzd\u00e1lenosti uveden\u00fdch v tab. \u010d. 3.<\/li>\n<\/ul>\n<table>\n<caption>Tabulka \u010d. 2: Vzd\u00e1lenost mezi vodi\u010di a vegetac\u00ed pro proveden\u00ed z\u00e1sahu<\/caption>\n<tbody>\n<tr>\n<th>Jmenovit\u00e9 nap\u011bt\u00ed<\/th>\n<th>Typ vodi\u010d\u016f<\/th>\n<th>Mezn\u00ed stav vodi\u010d\u016f od porostu pro proveden\u00ed z\u00e1sahu (m)<\/th>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Veden\u00ed NN do AC 1kV<\/td>\n<td>hol\u00e9 vodi\u010de (B)<\/td>\n<td>2,0<\/td>\n<\/tr>\n<tr>\n<td>vodi\u010de se z\u00e1kladn\u00ed izolac\u00ed (C)<\/td>\n<td>1,5<\/td>\n<\/tr>\n<tr>\n<td>izolovan\u00fd kabelov\u00fd syst\u00e9m (I)<\/td>\n<td>1,5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Veden\u00ed VN nad AC 1kV do AC 45 kV v\u010detn\u011b<\/td>\n<td>hol\u00e9 vodi\u010de (B)<\/td>\n<td>3,6<\/td>\n<\/tr>\n<tr>\n<td>vodi\u010de se z\u00e1kladn\u00ed izolac\u00ed (C)<\/td>\n<td>3,0<\/td>\n<\/tr>\n<tr>\n<td>izolovan\u00fd kabelov\u00fd syst\u00e9m (I)<\/td>\n<td>2,5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Veden\u00ed VVN nad AC 45 kV do 110 kV v\u010detn\u011b<\/td>\n<td>4,5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption>Tabulka \u010d. 3:<\/caption>\n<tbody>\n<tr>\n<th>Druh stanice<\/th>\n<th>Ochrann\u00e9 p\u00e1smo<\/th>\n<\/tr>\n<tr>\n<td>U venkovn\u00edch el. stanic a stanic s nap\u011bt\u00edm vy\u0161\u0161\u00edm ne\u017e 52 kV v budov\u00e1ch<\/td>\n<td>20 m od oplocen\u00ed nebo vn\u011bj\u0161\u00edho l\u00edce obvodov\u00e9ho zdiva<\/td>\n<\/tr>\n<tr>\n<td>U sto\u017e\u00e1rov\u00fdch el. stanic a v\u011b\u017eov\u00fdch stanic s venkovn\u00edm p\u0159evodem nap\u011bt\u00ed z \u00farovn\u011b nad 1kV a men\u0161\u00ed ne\u017e 52kV<\/td>\n<td>7 m od vn\u011bj\u0161\u00ed strany p\u016fdorysu stanice ve v\u0161ech sm\u011brech<\/td>\n<\/tr>\n<tr>\n<td>U kompaktn\u00edch a zd\u011bn\u00fdch el. stanic s p\u0159evodem nap\u011bt\u00ed z \u00farovn\u011b nad 1kV a men\u0161\u00ed ne\u017e 52kV<\/td>\n<td>2 m od vn\u011bj\u0161\u00edho pl\u00e1\u0161t\u011b stanice ve v\u0161ech sm\u011brech<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Doba proveden\u00ed z\u00e1sahu<\/h2>\n<ul>\n<li>K\u00e1cen\u00ed d\u0159evin mimo les se prov\u00e1d\u00ed zpravidla v dob\u011b vegeta\u010dn\u00edho klidu vyjma p\u0159\u00edpadu, kdy spr\u00e1vn\u00ed org\u00e1n umo\u017en\u00ed k\u00e1cen\u00ed mimo obdob\u00ed vegeta\u010dn\u00edho klidu.<\/li>\n<li>K\u00e1cen\u00ed d\u0159evin v lese se prov\u00e1d\u00ed celoro\u010dn\u011b.<\/li>\n<li>O\u0159ez v\u011btv\u00ed je mo\u017en\u00fd celoro\u010dn\u011b. Doporu\u010den\u00e9 obdob\u00ed je v\u0161ak prvn\u00ed polovina vegeta\u010dn\u00edho obdob\u00ed \u2013 tedy obdob\u00ed od b\u0159ezna do \u010dervna. O\u0159ez v zimn\u00edm obdob\u00ed (doba vegeta\u010dn\u00edho klidu) se nedoporu\u010duje.<\/li>\n<\/ul>\n<p>Obdob\u00ed vegeta\u010dn\u00edho klidu nen\u00ed jednozna\u010dn\u011b stanoveno v \u017e\u00e1dn\u00e9m pr\u00e1vn\u00edm p\u0159edpise a z\u00e1le\u017e\u00ed na m\u00edstn\u00edm org\u00e1nu ochrany p\u0159\u00edrody, kter\u00fd toto m\u016f\u017ee stanovit v r\u00e1mci sv\u00e9ho stanoviska k \u017e\u00e1dostem o povolen\u00ed nebo ozn\u00e1men\u00ed k\u00e1cen\u00ed. V\u00fdjimku tvo\u0159\u00ed p\u0159\u00edpady, kdy je d\u0159evinou p\u0159\u00edmo ohro\u017een provoz nadzemn\u00edch veden\u00ed.<\/p>\n<h2>Podm\u00ednky pro prov\u00e1d\u011bn\u00ed odstran\u011bn\u00ed a okle\u0161t\u011bn\u00ed d\u0159evin a jin\u00fdch porost\u016f<\/h2>\n<p>Osoba, kter\u00e1 bude prov\u00e1d\u011bt z\u00e1sah do stromov\u00ed, se p\u0159i jeho realizaci nesm\u00ed za \u017e\u00e1dn\u00fdch okolnost\u00ed jakoukoli \u010d\u00e1st\u00ed sv\u00e9ho t\u011bla \u010di pou\u017eit\u00fdmi pracovn\u00edmi prost\u0159edky a jin\u00fdmi v\u011bcmi p\u0159ibl\u00ed\u017eit k \u017eiv\u00fdm \u010d\u00e1stem veden\u00ed na vzd\u00e1lenosti bli\u017e\u0161\u00ed, ne\u017e je <strong>Bezpe\u010dn\u00e1 vzd\u00e1lenost od veden\u00ed uveden\u00e1 v tabulce \u010d. 4<\/strong>. Tyto vzd\u00e1lenosti plat\u00ed jak pro osobu prov\u00e1d\u011bj\u00edc\u00ed z\u00e1sah, tak pro ve\u0161ker\u00e9 stroje, n\u00e1stroje, zdvihac\u00ed a mont\u00e1\u017en\u00ed za\u0159\u00edzen\u00ed a mus\u00ed b\u00fdt odvozeny od nejbli\u017e\u0161\u00edch vodi\u010d\u016f pod nap\u011bt\u00edm jak ve vodorovn\u00e9m tak ve svisl\u00e9m sm\u011bru dle jmenovit\u00e9ho nap\u011bt\u00ed vodi\u010d\u016f. Z\u00e1sah se nesm\u00ed prov\u00e1d\u011bt v p\u0159\u00edpadech, kdy p\u0159ed z\u00e1sahem v\u011btve stromu a jin\u00e9ho porostu, strom \u010di jin\u00fd porost zasahuje do veden\u00ed, nebo kdy p\u0159i prov\u00e1d\u011bn\u00ed z\u00e1sahu m\u016f\u017ee padaj\u00edc\u00ed v\u011btev, strom \u010di jin\u00fd porost zas\u00e1hnout veden\u00ed.<\/p>\n<table>\n<caption>Tabulka \u010d. 4: Bezpe\u010dn\u00e1 vzd\u00e1lenost od veden\u00ed<\/caption>\n<tbody>\n<tr>\n<th>Jmenovit\u00e1 nap\u011bt\u00ed AC<\/th>\n<th>Bezpe\u010dn\u00e1 vzd\u00e1lenost od veden\u00ed<\/th>\n<\/tr>\n<tr>\n<td>Veden\u00ed NN do AC 1kV<\/td>\n<td>1 m<\/td>\n<\/tr>\n<tr>\n<td>Veden\u00ed VN nad AC 1kV do AC 45 kV v\u010detn\u011b<\/td>\n<td>2 m<\/td>\n<\/tr>\n<tr>\n<td>Veden\u00ed VVN nad AC 45 kV do 110 kV v\u010detn\u011b<\/td>\n<td>3 m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>V p\u0159\u00edpad\u011b, \u017ee osoba prov\u00e1d\u011bj\u00edc\u00ed z\u00e1sah nem\u016f\u017ee dodr\u017eet z\u00e1sady uveden\u00e9 shora, mus\u00ed u z\u00e1sahu zajistit osobu s p\u0159\u00edslu\u0161nou elektrotechnickou kvalifikac\u00ed dle vyhl. \u010d. 50\/1978 Sb., v platn\u00e9m zn\u011bn\u00ed, kter\u00e1 bude prov\u00e1d\u011bt dozor a odpov\u00eddat za bezpe\u010dnost z\u00e1sahu, nebo po\u017e\u00e1dat provozovatele distribu\u010dn\u00ed soustavy spole\u010dnost E.ON Distribuce, a.s. o vypnut\u00ed nadzemn\u00edho veden\u00ed.<\/p>\n<p>V p\u0159\u00edpad\u011b p\u00e1du stromu \u010di jin\u00e9ho porostu v\u010detn\u011b jejich v\u011btv\u00ed do nadzemn\u00edho veden\u00ed mus\u00ed osoba prov\u00e1d\u011bj\u00edc\u00ed z\u00e1sah:<\/p>\n<ul>\n<li>bezodkladn\u011b p\u0159eru\u0161it prov\u00e1d\u011bn\u00fd z\u00e1sah<\/li>\n<li>nedot\u00fdkat se stromu \u010di jin\u00e9ho porostu nebo jejich v\u011btv\u00ed, kter\u00e9 jsou v kontaktu s nadzemn\u00edm veden\u00edm<\/li>\n<li>opustit pracovi\u0161t\u011b<\/li>\n<li>o vznikl\u00e9m mimo\u0159\u00e1dn\u00e9m stavu informovat na telefon\u00edm \u010d\u00edsle <a href=\"tel:+420800225577\">800 22 55 77<\/a> poruchovou slu\u017ebu<\/li>\n<li>vy\u010dkat na p\u0159\u00edjezd zam\u011bstnance E.ON Distribuce, a.s., kter\u00fd rozhodne o dal\u0161\u00edm zp\u016fsobu pokra\u010dov\u00e1n\u00ed v z\u00e1sahu<\/li>\n<\/ul>\n<p>Je zak\u00e1zan\u00e9 prov\u00e1d\u011bt pr\u00e1ce, p\u0159i kter\u00fdch nen\u00ed mo\u017en\u00e9 dodr\u017eet podm\u00ednky bezpe\u010dnosti pr\u00e1ce, zejm\u00e9na p\u0159i nevyhovuj\u00edc\u00edch atmosf\u00e9rick\u00fdch podm\u00ednk\u00e1ch (bou\u0159e, siln\u00fd v\u00edtr, mlha, d\u00e9\u0161\u0165 apod.), ve st\u00edsn\u011bn\u00fdch prostor\u00e1ch a prostor\u00e1ch s nevyhovuj\u00edc\u00edm prost\u0159ed\u00edm.<\/p>\n<p>V p\u0159\u00edpad\u011b pot\u0159eby je nutn\u00e9 zajistit d\u0159eviny proti p\u00e1du do veden\u00ed vhodn\u00fdmi prost\u0159edky (lana, provazy).<\/p>\n<p>Je zak\u00e1z\u00e1no prov\u00e1d\u011bt ve\u0161ker\u00e9 pozemn\u00ed pr\u00e1ce, p\u0159i kter\u00fdch by byly naru\u0161ena stabilita sloup\u016f nebo sto\u017e\u00e1r\u016f.<\/p>\n<p>Z\u00e1sah mus\u00ed b\u00fdt proveden v souladu s p\u0159\u00edslu\u0161n\u00fdmi ustanoven\u00edmi z\u00e1k. \u010d. 114\/1992 Sb., zejm\u00e9na nesm\u00ed v d\u016fsledku z\u00e1sahu doj\u00edt k po\u0161kozen\u00ed d\u0159evin.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>V\u00e1\u017een\u00ed vlastn\u00edci a u\u017eivatel\u00e9 pozemk\u016f, dovolte, abychom v\u00e1s upozornili na nutnost dodr\u017een\u00ed z\u00e1kona \u010d. 458\/2000 Sb. (energetick\u00fd z\u00e1kon) a povinnosti, kter\u00e9 z n\u011bj plynou. Na z\u00e1klad\u011b tohoto z\u00e1kona a dle platn\u00fdch norem (PNE 33 0000-6, PNE 33 3300, PNE 33<a class=\"read-more\" href=\"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/nezarazene\/odstraneni-drevin-ohrozujici-bezpecny-a-spolehlivy-provoz-elektrickeho-distribucniho-zarizeni\/\">&#8230;&nbsp;\u010d\u00edst v\u00edce<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1080","post","type-post","status-publish","format-standard","hentry","category-nezarazene"],"_links":{"self":[{"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/posts\/1080"}],"collection":[{"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/comments?post=1080"}],"version-history":[{"count":9,"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/posts\/1080\/revisions"}],"predecessor-version":[{"id":1114,"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/posts\/1080\/revisions\/1114"}],"wp:attachment":[{"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/media?parent=1080"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/categories?post=1080"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ususi.vrankova-devel.cz\/subdom\/ususi\/wp-json\/wp\/v2\/tags?post=1080"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}